FMS Configuration Data Group Mapping

The following table aligns "FMS Configuration" data items with Totaflow device data groups and elements they map to.

See EFM Data Items for more information.

Data Group Element Description FMS Item String Native Data Group Native Data Group Element
cfg001 Meter Type eFMS_CFG_METER_TYPE Meter Configuration ArcTypT
PrmElmT if Cone
cfg002 Primary Calc Method eFMS_CFG_CALC_METHOD_PRIMARY Meter Configuration VolClc
PrmElmT if Cone
cfg003 Compressibility Calc Method eFMS_CFG_CALC_METHOD_FPV Meter Configuration ZMeth
cfg007 Meter ID eFMS_CFG_METER_ID Meter Configuration HdrFcuId
cfg008 Meter Description eFMS_CFG_METER_DESC Meter Configuration HdrLoc
cfg009 Contract Hour eFMS_CFG_CONTRACT_HOUR Meter Configuration ContHr
cfg010 Base Pressure eFMS_CFG_BASE_PRESSURE Meter Configuration PBase
cfg011 Base Temperature eFMS_CFG_BASE_TEMPERATURE Meter Configuration TBase
cfg012 Meter Tube Inside Diameter eFMS_CFG_METER_TUBE_INSIDE_DIAMETER Meter Configuration PipeSz
cfg013 Meter Tube Reference Temperature eFMS_CFG_METER_TUBE_REF_TEMP Meter Configuration PpRfTp
cfg015 Orifice Plate Bore Size eFMS_CFG_ORIFICE_PLATE_BORE_SIZE Meter Configuration OrfSize
cfg016 Orifice Plate Reference Temperature eFMS_CFG_ORIFICE_PLATE_REF_TEMP Meter Configuration OrfRfTp
cfg017 Orifice Plate Material eFMS_CFG_ORIFICE_PLATE_MATERIAL Meter Configuration MonOrf
cfg018 Cone Diameter eFMS_CFG_CONE_DIAMETER Meter Configuration OrfSize
cfg019 Cone Reference Temperature eFMS_CFG_CONE_REF_TEMP Meter Configuration OrfRfTp
cfg020 Cone Material eFMS_CFG_CONE_MATERIAL Meter Configuration MonOrf
cfg021 DP Taps Type eFMS_CFG_DP_TAPS_TYPE Meter Configuration TapTyp
cfg022 SP Tap Location eFMS_CFG_SP_TAP_LOCATION Meter Configuration TapLoc
cfg023 SP Sensor Type eFMS_CFG_SP_SENSOR_TYPE N/A Absolute only
cfg024 Atmospheric Pressure eFMS_CFG_ATMOSPHERIC_PRESSURE Meter Configuration Barom
cfg025 Meter factor eFMS_CFG_METER_FACTOR Meter Configuration Faux
cfg026 K factor eFMS_CFG_GAS_K_FACTOR_VOLUME(previously eFMS_CFG_K_FACTOR) Meter Configuration KFact
cfg027 Discharge Coefficient eFMS_CFG_DISCHARGE_COEFFICIENT Meter Configuration FixedCd
cfg028 Variables included in IV eFMS_CFG_INTEGRAL_VALUE_VARIABLES Meter Configuration VolClc
PrmElmT if Cone
cfg030 Methane eFMS_CFG_METHANE Meter Configuration Methane
cfg031 Ethane eFMS_CFG_ETHANE Meter Configuration Ethane
cfg032 Propane eFMS_CFG_PROPANE Meter Configuration Propane
cfg033 Isobutane eFMS_CFG_ISOBUTANE Meter Configuration IButane
cfg034 n-Butane eFMS_CFG_N_BUTANE Meter Configuration NButane
cfg035 Isopentane eFMS_CFG_ISOPENTANE Meter Configuration IPentan
cfg036 n-Pentane eFMS_CFG_N_PENTANE Meter Configuration NPentan
cfg038 n-Hexane eFMS_CFG_N_HEXANE Meter Configuration NHexane
cfg039 n-Heptane eFMS_CFG_N_HEPTANE Meter Configuration NHeptan
cfg040 n-Octane eFMS_CFG_N_OCTANE Meter Configuration NOctane
cfg041 n-Nonane eFMS_CFG_N_NONANE Meter Configuration NNonane
cfg042 n-Decane eFMS_CFG_N_DECANE Meter Configuration NDecane
cfg043 Nitrogen eFMS_CFG_NITROGEN Meter Configuration N2
cfg044 Carbon Dioxide eFMS_CFG_CARBON_DIOXIDE Meter Configuration CO2
cfg045 Water eFMS_CFG_WATER Meter Configuration H2o
cfg046 Hydrogen Sulfide eFMS_CFG_HYDROGEN_SULFIDE Meter Configuration H2s
cfg047 Hydrogen eFMS_CFG_HYDROGEN Meter Configuration Hydrog
cfg048 Carbon Monoxide eFMS_CFG_CARBON_MONOXIDE Meter Configuration Co
cfg049 Oxygen eFMS_CFG_OXYGEN Meter Configuration Oxygen
cfg050 Helium eFMS_CFG_HELIUM Meter Configuration Helium
cfg051 Argon eFMS_CFG_ARGON Meter Configuration Argon
cfg055 Heating Value - Volume eFMS_CFG_HEATING_VALUE_VOLUME Meter Configuration Btu
cfg058 Relative Density eFMS_CFG_RELATIVE_DENSITY Meter Configuration Gravity
cfg061 Viscosity eFMS_CFG_VISCOSITY Meter Configuration Visc
cfg075 Orifice Coefficient of Thermal Expansion eFMS_CFG_ORIFICE_COEFFICIENT_THERMAL_EXPANSION Meter Configuration OrifExp
cfg076 Pipe Coefficient of Thermal Expansion eFMS_CFG_PIPE_COEFFICIENT_THERMAL_EXPANSION Meter Configuration PipeExp
cfg082 Isentropic Exponent eFMS_CFG_ISENTROPIC_EXPONENT Meter Configuration Rsph
cfg083 Standard Air Compressibility eFMS_CFG_BASE_COMPRESSIBLITY_OF_AIR Meter Configuration Zba
cfg084 Use Live Temperature eFMS_CFG_USE_LIVE_TEMP Meter Configuration UseMeTp
cfg089 Low Flow Cutoff (DP) eFMS_CFG_LOW_FLOW_CUTOFF_DP Meter Configuration ZeroCut
cfg106 DP Alarm Low eFMS_CFG_DP_ALARM_LOW Meter Configuration DpLoLim
cfg107 DP Alarm High eFMS_CFG_DP_ALARM_HIGH Meter Configuration DpHiLim
cfg108 SP Alarm Low eFMS_CFG_SP_ALARM_LOW Meter Configuration SpLoLim
cfg109 SP Alarm High eFMS_CFG_SP_ALARM_HIGH Meter Configuration SpHiLim
cfg110 Temp Alarm Low eFMS_CFG_TEMP_ALARM_LOW Meter Configuration TfLoLim
cfg111 Temp Alarm High eFMS_CFG_TEMP_ALARM_HIGH Meter Configuration TfHiLim
cfg112 Flow Rate Alarm Low eFMS_CFG_FLOW_RATE_ALARM_LOW Meter Configuration FlLoLim
cfg113 Flow Rate Alarm High eFMS_CFG_FLOW_RATE_ALARM_HIGH Meter Configuration FlHiLim
cfg115 DP Calibrate Low eFMS_CFG_DP_CALIBRATE_LOW Meter Configuration DpLoCal
cfg116 DP Calibrate High eFMS_CFG_DP_CALIBRATE_HIGH Meter Configuration DpHiCal
cfg117 SP Calibrate Low eFMS_CFG_SP_CALIBRATE_LOW Meter Configuration SpLoCal
cfg118 SP Calibrate High eFMS_CFG_SP_CALIBRATE_HIGH Meter Configuration SpHiCal
cfg127 K Factor Mass eFMS_CFG_GAS_K_FACTOR_MASS Meter Configuration KMass
cfg130 Cone Coefficient of Thermal Expansion eFMS_CFG_CONE_COEFFICIENT_THERMAL_EXPANSION    
cfg513 Sample Type eFMS_CFG_SAMPLE_TYPE Meter Configuration StrmAtt
cfg517 Accumulated Volume eFMS_CFG_ACCUMULATED_VOLUME Basic Poll CurAccVol
cfg518 Meter Serial Number eFMS_CFG_METER_SERIAL_NUMBER Meter Configuration MtrBodySer
cfg525 DP Calibrate Mid eFMS_CFG_DP_CALIBRATE_MID Meter Configuration DpMCal
cfg526 SP Calibrate Mid eFMS_CFG_SP_CALIBRATE_MID Meter Configuration SpMHCal
cfg539 Liquid Calculation Method eFMS_CFG_LIQUID_CALC_METHOD TBD TBD
cfg542 Liquid K-Factor (Volume) eFMS_CFG_LIQ_K_FACTOR_VOLUME Meter Configuration KLiquid
cfg543 Liquid K-Factor (Mass) eFMS_CFG_LIQ_K_FACTOR_MASS Meter Configuration KLiquid
cfg544 Product Index eFMS_CFG_LIQUID_PRODUCT_INDEX Meter Configuration LiquidType

Back to top